sokomo models software hardware Request a quote
Models

Two models, sized to the load.

MDX230
HIGH-TORQUE · 3.0 A / MOTOR

The workhorse. Full 3.0 A per motor for torque to start heavier product and more usable speed under load — where most two-zone cards cap at 2.5 A.

3.0 A
PER MOTOR
12
ZONES / SUPPLY BOX
MDX220
LONG-REACH · 2.0 A / MOTOR

The density play. At 2.0 A per motor, more modules chain from a single supply — for lighter loads and longer runs of zones per drop.

2.0 A
PER MOTOR
16
ZONES / SUPPLY BOX
Where they differ
MDX220
MDX230
Current / motor
2.0 A
3.0 A
Positioning
Long-reach
High-torque
Zones / supply box
16
12

See the power architecture below for how far each model reaches from one supply.

Shared across the line

Both models share the field interface, enclosure, and mounting — so a line can mix them freely.

ZONES2, independently controlled
NETWORKEtherNet/IP · dual RJ-45
MOTORS2 × 24 V BLDC + Hall
POWER IN24 V DC · keyed power cordset
MOTOR CONN.Keyed motor cordset · per zone
SENSORSSealed port · 1/zone · 2 sensors each via splitter
ENCLOSURESealed moulded shell · IP54
CONTROL MODESPLC-direct · onboard ZPA
DRIVE PROFILESSpeed · Hybrid · Torque
DIMENSIONS168 × 95 × 29 mm
MOUNTINGDIN rail · clip-on
INDICATORS3 LEDs · PWR/MS/NS + OLED
Power architecture

One supply, a run of zones.

High voltage travels to a conveyor-mounted supply box; only short 24 V cordsets leave it, chaining module to module. Both models share the same supply, connectors, and cabling — the lower-current model simply reaches further.

DISTRIBUTION TOPOLOGY
480 V 3φ
long run · low drop
SUPPLY BOX · 480 V → 24 V · CONVEYOR-MOUNTED
PSU A
24 V · 20 A → CIRCUIT A
PSU B
24 V · 20 A → CIRCUIT B
CIRCUIT A · 20 A
MDX230
2-ZONE MODULE
ZONE 1
ZONE 2
MDX230
2-ZONE MODULE
ZONE 3
ZONE 4
MDX230
2-ZONE MODULE
ZONE 5
ZONE 6
CIRCUIT B · 20 A
MDX230
2-ZONE MODULE
ZONE 1
ZONE 2
MDX230
2-ZONE MODULE
ZONE 3
ZONE 4
MDX230
2-ZONE MODULE
ZONE 5
ZONE 6
ONE SUPPLY BOX = 6 MODULES = 12 ZONES
CIRCUIT A · 20 A
MDX220
2-ZONE MODULE
Z1
Z2
MDX220
2-ZONE MODULE
Z3
Z4
MDX220
2-ZONE MODULE
Z5
Z6
MDX220
2-ZONE MODULE
Z7
Z8
CIRCUIT B · 20 A
MDX220
2-ZONE MODULE
Z1
Z2
MDX220
2-ZONE MODULE
Z3
Z4
MDX220
2-ZONE MODULE
Z5
Z6
MDX220
2-ZONE MODULE
Z7
Z8
ONE SUPPLY BOX = 8 MODULES = 16 ZONES
01

24 V made locally

At 24 V, voltage drop — not current — caps cable length. High voltage runs the distance to a conveyor-mounted box; only short 24 V cordsets leave it.

02

One circuit, three modules

The power cordset gangs three pins per rail at ~6 A each. Three MDX230 modules draw ~18 A across the 20 A circuit and series-chain straight through — no separate power trunk.

03

Reach on the same circuit

Same 20 A circuit, same connectors: MDX230 runs three modules, and the lighter 4 A MDX220 reaches four — so a denser line needs no different power hardware.

// Recommended continuous loading per 20 A circuit: MDX230 three modules (18 A), MDX220 four (16 A); two circuits per supply box. Connector/wire ceiling is higher but not advised for continuous conveyor duty.